The Realtime log displays debugging information for different interfaces.
These logs are stored in RAM memory and are cleared on reboot.
This logging is a time consuming task and can slow down the overall behavior of your Ewon device. While some logging is enabled by default, activating additional debugging interfaces should only be done at the request of your support contact and only during the debugging process.
Information about enabling debugging or modifying debugging levels can be found:
- For VPN
- For Wi-Fi
- for Modem
- For Serial communications
Display Filters
You can use the fields at the top of the screen to control which entries are displayed.
- Filter
-
Free text filter. All five columns are taken into consideration.
- Items to display
-
Limit the number of items to show.
- Source
-
Filter the events based on their interface.
Display Fields
Each entry in the log includes the following fields:
- Time
-
The time and date when the event occurred.
- Source
-
The interface or process that triggered the event.
- Event
-
The unique ID for the event.
- Clock
-
The time in msec since the Ewon device has booted.
- Event Id
-
A unique index for this event. These are reset at reboot.