i4scada Version 3.8.0
Check out the Changes and Fixed Bugs of i4scada 3.8.0 Version. The first i4scada version which brings along a large amount of improvements and bug fixes.
Changes
ID | Description |
---|---|
SWC00074-8 | Implement new Licensing environment |
SWC00074-412 | Re-style Infragistics controls from i4scada applications |
SWC00074-679 | Improve the development process of custom WEBfactory components extensions in SmartEditor |
SWC00074-695 | Add IoT support in SCADA |
SWC00074-722 | Improve the HTML Alarming components |
SWC00074-752 | Implement an IoT Hubconnector for SCADA (online and historical values) |
SWC00074-911 | Implement the HTML MessengerPro |
SWC00074-912 | Implement the HTML SchedulerPro |
SWC00074-1017 | Port Static Symbols to the SVG Library |
SWC00074-1240 | Add states property to all SVG extensions |
SWC00074-1251 | Update the SmartEditor fonts |
SWC00074-1411 | Improve the HTML components |
SWC00074-1523 | Extend the wf-core extension and i4scada App Template to support configuration of a remote server |
SWC00074-2691 | Improve the Silverlight Alarming components |
SWC00074-77 | Create and maintain a set of reusable HTML widgets for WEBfactory visualisations in WYSIGWYG Web Builder |
SWC00074-181 | Enabled secured WCF webservices |
SWC00074-2690 | Improve the Silverlight version of the trending control |
SWC00074-262 | Update Packages and test the functionality and UI afterwards |
SWC00074-305 | Add support in Blend 2015 |
SWC00074-369 | Update project to work with latest type script version |
SWC00074-437 | Improve the wf-state-indicator state properties to be more flexible |
SWC00074-461 | Add dropdownAlignment to wfLanguageDropdown and wfWriteValueCombobox |
SWC00074-464 | Improve the performance of the domain login |
SWC00074-510 | Implement possibility to apply translation of the wf-alarm-viewer static text |
SWC00074-527 | Implement possibility to apply translation of the wf-chart static text |
SWC00074-528 | Implement possibility to apply translation of the wf-log-table static text |
SWC00074-530 | Implement possibility to apply translation of the wfLogbook / wf-logbook static text |
SWC00074-577 | Change the position of apply filters button in wfLogTagTable, alarmViewer |
SWC00074-581 | wf-alarm-viewer / wfAlarmViewer should show the alarm priority label |
SWC00074-615 | wfLogTagTable / wf-log-table - Implement "Apply button" in the same way as in wf-chart-1 |
SWC00074-658 | Create IoT icon for all brands |
SWC00074-684 | Update wf-core and WEBfactory extensions and create new i4scada SE bundle |
SWC00074-760 | Implement the wf-switch-3-states component |
SWC00074-771 | wf-button / wfWriteValueButton should support symbolic, translateable text |
SWC00074-771 | wf-button / wfWriteValueButton should support symbolic, translateable text |
SWC00074-859 | Change the naming of widget "wfToggleSwitch3States" to be correct and consistent |
SWC00074-879 | Implement a version property for extensions using icon and symbol fonts |
SWC00074-935 | Add the WCS OPC Server to the i4scada setup |
SWC00074-963 | Review and adjust the UI of wf-signal-list components |
SWC00074-965 | wf-user-login extension - Change the userProperties to be a dataset |
SWC00074-1137 | Extensions should support bootstrap class "btn-link" |
SWC00074-1142 | WF-button extension should support "toggle" mode as in old Silverlight button |
SWC00074-1144 | WF-button "increment mode" should have a "overflow" property where the value is resetted |
SWC00074-1194 | Update the design view of wf-alarm-viewer extension |
SWC00074-1195 | Update the design view of wf-log-table extension |
SWC00074-1196 | Update the design view of wf-chart extension |
SWC00074-1198 | wf-logbook / wfLogBook - change the topic input field to a dropdown |
SWC00074-1203 | Extend extensions with new properties "initialConfiguration" and "configurationNamespace" |
SWC00074-1204 | Extend the wf-log-table extension to support the property "logTags" |
SWC00074-1208 | Update the property "defaultEntryTopic" in wf-logbook extension |
SWC00074-1216 | Add description for axis min and max signal properties |
SWC00074-1230 | Implement wf-signal-list extension |
SWC00074-1231 | Implement secured container extension based on wf-secured-container |
SWC00074-1241 | wf-navigation-button extension has some styling issues at design and runtime |
SWC00074-1254 | i4scada App Template - Extend popover title |
SWC00074-1281 | Create a preview image and toolbox icon for wf-secured-layer, wf-enable-layer, wf-visible-layer extensions |
SWC00074-1288 | i4scada App Template - Add styles for positioning the navigation bar on the bottom |
SWC00074-1369 | Implement wf-toggle-button extension |
SWC00074-1370 | wfUserLogin / wf-user-login - improve UX |
SWC00074-1371 | wf-signal-list should have also a property for initial configuration like e.g. wf-chart |
SWC00074-2607 | wf-alarm-viewer should support multiple groups and types |
SWC00074-2706 | Improve draggable behavior to generate and store complete css for multiple elements |
SWC00074-3138 | Update Beckhoff ADS connector setup |
SWC00074-3168 | Studio - Add signal counters in the status bar |
SWC00074-3684 | A user should be able to enable triggers on the alarm log inserts |
SWC00074-66 | Implement Multi-Language setup for SCADA |
SWC00074-36 | Update new icons in i4scada applications |
SWC00074-946 | Extend User Manager to receive the host name and port number through URL paramateres |
SWC00074-947 | Studio - add settings for host name and port number under the Project settings |
SWC00074-2559 | Add support for multiple states in wf-path, wf-state-image, wf-line and pipes extensions |
SWC00074-3105 | SIMATIC Connector change channelID |
SWC00074-3579 | Remove WFBargraph2 and WFBargraph3 from SmartEditor toolbox and mark them as obsolete in the Silverlight controls |
SWC00074-3171 | Implement a more performant (light weight) signals handling |
Fixed Bugs
ID | Description |
---|---|
SWC00074-389 | Type and Name properties are wrongly assigned in widget reference for wf-Button |
SWC00074-686 | wf-alarm-viewer / wfAlarmViewer alarm acknowledgement doesn't work |
SWC00074-1140 | WF-slider contains a min-height property of 200px which is too big |
SWC00074-1242 | SmartEditor / Standalone app - Signal values are not updating if a user is logged in |
SWC00074-1277 | User login popover close button is not in place |
SWC00074-1421 | i4scada App Template - Standalone publish output contains some obsolete images |
SWC00074-18 | AlarmViewer doesn't store date/time in filter configuration |
SWC00074-89 | Operation Diary Control doesn't refresh and remains empty when database is empty at the beginning |
SWC00074-157 | Signalbrowser in WFTrending3 Control takes 20-30 seconds for approx. 80 groups to be displayed |
SWC00074-244 | WFOutput1 is not visible at runtime if the LabelSymbolicText and the UnitSymbilocText is the same text |
SWC00074-307 | Bargraph widget - ticks are not inverted according to the orientation property |
SWC00074-393 | wf-logbook widget - Apply button overlaid bottom bar |
SWC00074-445 | Not all properties are correct resolved in wf-input extension |
SWC00074-450 | Some wf-bargraph properties cause a exception at runtime |
SWC00074-466 | The domain login is not working when groups have circular references |
SWC00074-475 | MaintenancePro - the failed logons are not handled during the login |
SWC00074-476 | MessengerPro - the failed logons are not handled during the login |
SWC00074-477 | ScenarioManagerPro - the failed logons are not handled during the login |
SWC00074-478 | SchedulerPro - the failed logons are not handled during the login |
SWC00074-508 | wf-alarm-viewer / wfAlarmViewer alarm detail dialog shows online alarm information instead offline |
SWC00074-524 | wfSlider - showTickLabels property cause reset of value range (0 - 100) |
SWC00074-525 | WEBfactory Studio VChannel Scripts are overwritten when mulitple signals are selected and modified |
SWC00074-554 | WEBfactory Studio "AlarmDetailsView" doesn't show save & cancel button |
SWC00074-555 | User Manager at the WFStudio is not working without port 80 at the IIS |
SWC00074-565 | Initial load of i4scada tries to load symbolic texts for each translation label |
SWC00074-580 | i4scada App Template - Replacement values are not working in popup of alarmViewer |
SWC00074-598 | Text color in Buttons with "normal" state are overwritten |
SWC00074-649 | WEBfactory Server sometimes doesn't update CollectiveAlarms |
SWC00074-675 | Some of components or webservice calls cause(s) big performance problem |
SWC00074-677 | wfAlarmViewer widget and wf-alarm-viewer component close button text in detail dialog is not correct |
SWC00074-678 | SymbolicTextsService translate doesn't work |
SWC00074-687 | wf-alarm-viewer component - AlarmStatus filter gets not resolved if symbolic value is used for filter property |
SWC00074-688 | wf-alarm-viewer - Not all static labels are translated in alarm details dialog |
SWC00074-708 | Pipes extensions - Minimum width & height of pipe extension should be smaller |
SWC00074-737 | i4scada SmartEditor - Background color - Image get overwritten |
SWC00074-741 | wf-language-selector should use WEBfactory specific icon |
SWC00074-742 | wfSecuredContainer / wf-secured-container is hidden even if no project authorization is configured |
SWC00074-748 | wfStateDisplay and wfStateText are not working |
SWC00074-750 | wfLogTagTrend and wf-chart-1 timestamps are not displayed correct if timezone of the server is different |
SWC00074-759 | Standalone package for wf-core extension contains CSS and images overhead |
SWC00074-769 | wf-language-selector size is different at runtime and designtime |
SWC00074-770 | wf-symbolictext causes a critical script error if it is used in a modal dialogs content |
SWC00074-873 | Value font-size in wf-arc gets overwritten at runtime |
SWC00074-915 | SmartEditor default styles for a:visited mess up styles from i4scada App Template |
SWC00074-916 | wf-alarm-vewer / wfAlarmViewer alarmGroup(s) and alarmType(s) properties are not implemented anymore |
SWC00074-926 | HTML Chart component and widget crashes if it is left for aprox 2 hours in autoUpdate mode |
SWC00074-955 | DB Export files from IET can't be Imported |
SWC00074-956 | Export Import Tool - fail to do diff with attached exported file |
SWC00074-960 | Log mode listed twice in the selection list |
SWC00074-992 | wf-shape state colors styles are incomplete in the i4scada App Template |
SWC00074-1036 | wf-slider overwrites styles from wf-bargraph extension |
SWC00074-1037 | Link visited styles are damaged by the default styles in SmartEditor |
SWC00074-1038 | HTML5 Widgets - Historical Data - translation is missing |
SWC00074-1104 | i4scada Smart Editor Filters are not taken into consideration |
SWC00074-1136 | Options Select/Unselect all trigger an Error while saving data |
SWC00074-1189 | The timer for calling GetUTCLogValues is not cleared/stoped in wf-chart / wfLogTagTrend |
SWC00074-1191 | The Modal dialogs do not get cleared in i4scada App Template |
SWC00074-1199 | WF-Vertical bar has an Y offset between design time and runtime in HTML5 SE |
SWC00074-1201 | WF-vertical bargraph ticks are visible even Ticks label with ist set to 0 |
SWC00074-1202 | Binding issues at level of wfAckAlarmButton |
SWC00074-1224 | wf-language-selector: Style -> CSS Class Name is not working at runtime, only at design time |
SWC00074-1229 | wf-logbook extension - Design tiem preview is different with runtime |
SWC00074-1249 | Text Alignment of wf-symbolictext extension is not used during runtime |
SWC00074-1252 | wf-sensor doesn't show state color correctly, angle / rotation property is not applied at runtime |
SWC00074-1253 | Subchart Visibility property doesn't work at design time correctly |
SWC00074-1275 | Cannot Close modal dialog, property "overflow" missing |
SWC00074-1290 | wf-enable-container / wf-visibility-container - doesn't work if the condition signal value is set to 0 |
SWC00074-1293 | wfuserLogin / wf-user-login - defaultText is not translatable |
SWC00074-1296 | Fix the style for modal dialog title |
SWC00074-1368 | wf-signal-list - handling of string values is not possible |
SWC00074-1377 | wf-user-login - Change password collapsible control button doesn't work in components |
SWC00074-2605 | esmartZoom binding handler does not unregister events properly |
SWC00074-2920 | wf-popover shows the 'arrow' incorrect at the first time |
SWC00074-2922 | esmartzoom plugin centre object incorrect and resize doesn't work after return to page |
SWC00074-2947 | To add states dynamically at runtime doesn't work |
SWC00074-2959 | wf-chart-1 - CSV export doesn't work in Internet Explorer and Firefox |
SWC00074-3006 | Setup assistant - SQL Server installation selection |
SWC00074-3010 | Setup assistent - restart information typing error |
SWC00074-3012 | i4scada Studio: Silverlight information -> texts on the buttons are in English at a German system |
SWC00074-3018 | i4scada Studio: Enforce user authentication -> wrong German translation |
SWC00074-3036 | Studio: create new project -> text from error message is in English and German on a German system |
SWC00074-3042 | Logger: the "Deleting" information is missing, if the "Deleting" is not activated |
SWC00074-3060 | Server error: Not all parameters are set in xml configuration for "Servername" |
SWC00074-3073 | i4scada Studio: Script error if "Settings" area is opened |
SWC00074-3078 | Studio: "Messaging" for the Messenger is available |
SWC00074-3098 | Alarming: "Execute Script" is not working |
SWC00074-3104 | Smart Editor Silverlight version has the same name as the HTML Smart Editor |
SWC00074-3175 | wf-arc - LineThickness doesn't take a value 0 at runtime |
SWC00074-3184 | Setup fails because of wrong message: Older version of SQL server found |
SWC00074-3199 | Silverlight Smart Editor: Bargraphs project page is not loaded at a browser |
SWC00074-3201 | Silverlight Bargraph 2 + 3 are not working |
SWC00074-3208 | Operation Diary (SL): replacement values are not shown at the alarm text |
SWC00074-3209 | Operation Diary (SL): the language selection is not working |
SWC00074-3214 | AlarmViewer, AlarmStateManager, AlarmOnline (SL): the language selection is not working |
SWC00074-3313 | wf-arc arc inner radius overflow the div |
SWC00074-3351 | wf-bargraph-horizontal value isn't bold |
SWC00074-3365 | wf-bargraph-vertical title text missing |
SWC00074-3366 | wf-bargraph-vertical value isn't bold |
SWC00074-3369 | wf-date-time-picker unused propertie isModalDialogsDraggable |
SWC00074-3371 | wf-buffer-button have the name wf-button |
SWC00074-3379 | Silverlight Bargraph 2+3: the size at runtime is not ok |
SWC00074-3387 | wf-combobox propertie translate mistake |
SWC00074-3392 | WF-combobox button custom css does not work |
SWC00074-3397 | wf-input icons not visible at design time |
SWC00074-3409 | WF-buffer-button Apperarance propertys dont work |
SWC00074-3410 | Translation issues - IoT Devices |
SWC00074-3411 | wf-gauge-1 scale overflow by value 200 |
SWC00074-3418 | wf-modal-dialog-button preview image missing |
SWC00074-3424 | WF-navigation-button tooltip text dont appear |
SWC00074-3425 | WF-navigation-button - design time / runtime behaviour is different |
SWC00074-3429 | WF-navigation-dropdown if button text containts an & the button is unavailable |
SWC00074-3439 | wf-signal-information signal property shows "[object]" as result |
SWC00074-3444 | wf-signal-information-popover signal property shows "[object]" as result |
SWC00074-3445 | wf-signal-information-popover - format property doesn't work |
SWC00074-3446 | wf-signal-information-popover icon custom css not work at runtime |
SWC00074-3451 | wf-slider position different at runtime and design time |
SWC00074-3454 | wf-slider write delay doesn't work |
SWC00074-3456 | wf-slider missing option at css class |
SWC00074-3458 | WF-input label width is at runtime bigger than set |
SWC00074-3461 | wf-state-indicator angle dont work correct at runtime |
SWC00074-3464 | wf-value-display dont show icons at designtime |
SWC00074-3465 | wf-value-display unit label width is at the wrong category |
SWC00074-3466 | WF-value-display label width is at runtime bigger than set |
SWC00074-3468 | Extension name in "wf-conveyor-C-turn" is not correct |
SWC00074-3470 | wf-modal-dialog-button modal dialog placement doesn't work |
SWC00074-3473 | WF-alarm-viewer custom css doesn't render at designtime |
SWC00074-3472 | WF-alarm-viewer button have at runtime not the bootstrap class |
SWC00074-3474 | WF-alarm-viewer missing property at the pdf docu |
SWC00074-3476 | WF-animation-layer tooltip property don't work at runtime |
SWC00074-3479 | wf-rotation-layer tooltip is not shown at runtime |
SWC00074-3480 | WF-rotation-layer start/end angle properties don't work at runtime |
SWC00074-3508 | UserManager: User Level is not visible with the default settings at the Studio |
SWC00074-3509 | User Manager Default Settings: at the "Auto Logoff interval" the numeric up/dwon function is missing |
SWC00074-3511 | User Manager: Select box for "Berechtigungsgruppen,..." is to small |
SWC00074-3516 | User Manager: the time span function is not working correctly |
SWC00074-3517 | User Manager: Access Group -> typing error in german version |
SWC00074-3526 | User Manager: different names at the menu "Kennwort ändern" at the german language |
SWC00074-3527 | User Manager: at "System Authorizations" the "Webapplications" and "VPlant"are visible -> are not supported at V3.8.0 |
SWC00074-3529 | User Manager: at "Authorization Groups" is the menu "Scheduler locations" visible |
SWC00074-3530 | User Manager: different names at the menu "Zugangsberechtigungen" at the german language |
SWC00074-3532 | Operation Diary: at "Benutzerverwaltungsereignisse" there is an english text at the german version |
SWC00074-3534 | User Manager: Privileged writing is not working correctly |
SWC00074-3535 | EventLog "WEBfactory" shows entries with the description "WF2006WebServices" |
SWC00074-3628 | i4scada Studio: User Manager is not working when i4scada server is not started |
SWC00074-3629 | Alarmviewer: texts at "Help" menu from a alarm is not changing the language |
SWC00074-3630 | Operation Diary: at the content filter menu the translation text for "Existing Users" is missing |
SWC00074-3631 | Operation Diary: at the content filter menu the German text for "Events" is missing |
SWC00074-3633 | Trending3: menu "Configure trend display" some German texts are missing |
SWC00074-3644 | Logger: the "Deleting" information is completly missing at the start |
SWC00074-3652 | User Manager: Access Groups the time span "01:00:00 - 23:00:00" is not working |
SWC00074-3663 | i4scada Studio: Alarming -> Invalid column name "i4Enabled" |
SWC00074-3737 | WF-Chart: problem with signalname -> Syntax error, unrecognized expression: .c3-line-0.1/Station_1.Motoren |
SWC00074-3954 | Studio is crashing when connecting to a database because of License |